POWER OPTIMIZATION SYSTEM

  • Our associate company - Power Matrix Solutions Pvt Ltd (PMX)has been in the field of providing solutions for Reactive Power Compensation and Harmonic Filtering from year 2000.
  • We have technical collaboration with three International companies for providing these solutions
  • PMX has its own Research & Development wing, who are responsible for designing the systems.

PMX manufactures the following products –

  • Electro Mechanical Contactor Based Power Factor Correction Systems
  • Thyristor Based Power Factor Correction Systems
  • Electro Mechanical Contactor Based Power Factor Correction Systems Fitted With Detuned Reactors
  • Thyristor Based Power Factor Correction Systems Fitted With Detuned Reactors
  • Neutral Current Elimination Systems
  • Detuned Reactors
  • APP and MPP type Capacitors
  • Customized Power Factor Solutions for High Voltage Applications

MaxPowerTM System

 

  • MxPowerTM Systems are Power Conditioning Systems very much essential in today electrical environment to Improve the Quality of electrical power used by the installations o Optimize electrical energy costs for installations
  • MaxPowerTM Systems are backed with a proven track record and failure free performance
  • MaxPowerTM Systems is an integrated system which is centrally controlled by a Microprocessor Based Regulator, The system is made up of multiple stages of L-R-C circuits configured to operate for a particular facility. These systems are the only systems in the world to use Variable – Non-Saturable- Zig Zag Reactors for harmonic mitigation and voltage correction
  • MaxPowerTM Systems are customized solutions and can be built to operate from 208 Volts to 345 KVolts, and the systems commissioned to date include loads as low as 100 KW to a MAX load of 3,100,000 KW.
  • MaxPowerTM Systems have a Self Diagnostic Feature (SDF), which identifies the component/status failure on a per stage and per phase basis, thereby allowing for instant remedial action.

What is MaxPowerTM?

MaxPowerTM is a state of the art energy saving and power conditioning system, with proven performance and satisfied customers in India. maxPowerTM is one of the few integrated modular system in the world specifically custom engineered to effectively and economically optimize power quality with guaranteed electric savings of up to 13%, without any disruptions to equipment or machinery

MaxPowerTM’s multistage system is triple protected, with each stage independently monitored, protected, and activated, resulting in simultaneous addressing of multiple problems and functions. This eliminates the need to purchase a number of different devices to correct each anomaly.

ADVANTAGES:

MaxPowerTM Power Conditioning System is 6 – In – One System providing –

S.N.O Features Optional Features
1 Voltage Improvement & Stability a) Brownout Protection
2 Three Phase Balancing         b) Intermittent Supply Failure Protection(upto 1 sec)
3 Surge & Transient Protection  
4 Broadband Harmonic Reduction  
5 Power Factor Improvement upto 0.98 to 1.00 c) Specific Harmonics Filtering
6 Energy Savings (3% to 12%) d) Phase Loss Synthesis

MaxPower™ Benefits

  • Reduces your facility’s power costs by up to 34% through reduction of KW Demand, KVA Demand, and KWH Consumption.
  • Protects your company investment in plant equipment and machinery.
  • Reduces equipment maintenance costs and improves productivity by reducing plant downtime due to equipment failure.
  • Balancing line voltages causes motor to run cooler, thereby extending motor life.
  • Makes it possible to increase the total connected load of a circuit, without increasing the size of the transformer or size of the conductors and protective equipment.
  • Harmonics, surges, and transients are eliminated or reduced and managed properly, thereby minimizing their effects on equipment and machinery.

Provides protection for plant and machineries and the likes of :

  • Computers
  • Process/Production Equipment
  • Electronic and Related Equipment
  • Variable Speed and Automatic Speed Drives
  • Sensitive Measuring and Diagnostic Equipment
  • Motors, Pumps, and Compressors
  • Lights and Ballasts
  • Transformers, Switchgears, and Electrical Distribution

To name a few of our clients in India

  • HSBC Bank – 1000 KW Load Demand – Achieved 5.5% Savings.
  • GE Capital International Services – 2500 KVA Load Demand – Achieved 7% Savings. Reduced the harmonic levels. Capacitors made obsolete.
  • Motorola India Ltd – 3000 KVA Load Demand – Achieved 4.8% Savings. Reduced the harmonics. Provided a power factor of 0.997.
  • Microsoft India Ltd - 5000 KVA Load Demand – Achieved 5.2% Savings. Reduced the harmonics. Provided a power factor of 0.997.
  • The Hindu – 500 KVA Load Demand. Reduced the harmonics by 50%. Energy Savings of 5.3%
  • Deccan Herald – 1000 KVA Load Demand. Reduced harmonics by almost 70%. Energy savings of more than 5%.
  • Johnson & Johnson India Ltd – 1500 KVA Load Demand. Energy Savings of 5.8%. Power Factor of 1.0. Harmonics THD reduced.
  • Glaxo Smithkline Beecham India Ltd – 1800 KVA Load Demand. Energy Savings of 5% to 6%. Harmonics Levels Reduced. Power Factor Improved to 1.0.
  • Wockhardt Ltd. - 500 KVA Load Demand. Energy Savings of 8%. Reduction in harmonic Levels, electronic component failures, power factor improved to 1.0.
  • S H Kelkar Ltd – 1500 KVA Load demand. Energy Savings of 5.5%. Reduction in failures of motors, compressors, power factor improved to 1.0
  • Many more ….such as Convergys, Ebizrate Services, Bank Of America, Lehman Brothers……